 a.Check if there is any leakage of air compressor or the material keeping gate is in position.

b.Material flow regulator setting volume (0.4MPA in generally )

c.The sensor should be installed fixed and clean. Clip and collision phenomenon should be prevented.

d.Replace the cylinder each year, O ring and sealing element (oil seal, piston ring ).

e.Whether the bag structure is flexible, if the bag is installed fixed. Remember to replace the rubber belt and high-strength canvas strip.

f.Clean up the air pipe, keep the pipe be dust absorbed. With excellent surge efficiency.